Highly crosslinked polyethylene
Cross-linked polyethylene, commonly abbreviated PEX, XPE or XLPE, is a form of polyethylene with cross-links. It is used predominantly in building services pipework systems, hydronic radiant heating and cooling systems, domestic water piping, insulation for high tension (high voltage) electrical cables, and baby play mats. It is also used for natural gas and offshore oil applications, chemical transportation, and transportation of sewage and slurries. PEX is an alternative to polyv… WebDec 17, 2024 · Highly cross-linked polyethylene (HXLPE) materials are developed specifically to reduce polyethylene wear and subsequent wear debris-induced osteolysis. …
Highly crosslinked polyethylene
Did you know?
WebExpanded polyethylene foam, also known as EPE, is a molded semi-rigid, non-crosslinked, closed-cell polyethylene foam that is often denser and stronger than its open-cell counter parts. Molded EPE planks are made with a very uniform cell structure. The consistent cell structure results in a foam with superior physical properties that have the ... WebHighly Resistant to Wear6-8. Proprietary electron beam process delivers 10Mrad dosage for greater crosslinking, resulting in superior long-term polyethylene wear performance …
WebNov 11, 2016 · Purpose Dual mobility cup (DMC) consists of a cobalt-chromium (CoCr) alloy cup articulated with a polyethylene (PE) mobile component capturing the femoral head in force using a snap-fit technique. This biomechanical study was the first to evaluate and compare the generation of cracks in the retentive area of DMC mobile components made … WebFeb 15, 2024 · Go to Brief Summary: The main objectives of this study are to confirm the long-term safety, performance, and clinical benefits of the G7 Acetabular Shells when used with the Vivacit-E and Longevity HXLPE liners and instrumentation in primary and revision total hip arthroplasty. Detailed Description:
WebHigh-density cross-linked polyethylene (HDXLPE) and cross-linked polyethylene (XPE) are medium-density polyethylene (MDPE) to HDPE containing cross-link bonds. These bonds … WebE-MAX is a step forward in the evolution of highly crosslinked polyethylene (XLPE) for orthopedic total joint bearing surfaces. Highly crosslinked A proven strategy for reducing in vivo wear [1-10] Mechanically annealed Eliminates* free radicals without the problems of melting [11,12] Vitamin E blended Intended to provide oxidative stability over time in vivo …
WebJun 18, 2024 · Osteolysis, attributed to polyethylene wear debris, is one of the main causes of aseptic loosening in THA (Jacobs et al. 2001).Since highly cross-linked polyethylene …
WebLongevity Highly Cross-linked Polyethylene Clinical Value Dossier. 97-7255-198-00 Rev.4-4-12 ML. 2012 Bragdon, C. et al ., Seven to Ten Year Follow-Up of Highly Crosslinked Polyethylene Liners in Total Hip Arthroplasty, Poster No. 2444, 55th Annual Meeting of the Orthopaedic Research Society, Las Vegas, 2009 pond siting reportWebMar 5, 2024 · 17-year follow-up study shows that highly cross-linked polyethylene (HXLPE) hip implants reduce wear by 90%. Rates of periprosthetic osteolysis are commensurately … pond siphonWebB. Highly Crosslinked UHMWPE (HXLPE) HXLPE originates from virgin resin powders or consolidated forms conforming to ASTM F648. This material type includes UHMWPE that has been highly... pond siphoningWebMar 5, 2024 · 17-year follow-up study shows that highly cross-linked polyethylene (HXLPE) hip implants reduce wear by 90%. Rates of periprosthetic osteolysis are commensurately low. The next follow-up study will be completed in three years, in order to take 20 years of continuous data into account. Periprosthetic osteolysis, or bone death, was the single ... shanty constructionWebMay 28, 2024 · According to the AOANJRR, 97.4% of THA primaries in 2024 with polyethylene acetabular bearing surfaces used cross-linked polyethylene (XLPE) that had … ponds in colorado springsWebProlong Highly Crosslinked Polyethylene represents a significant advance in wear reduction. Its resistance to wear provides a promising solution for TKA patients, … pond siphon videoWebnt demographic groups and two different measurement techniques have found that the femoral head penetration with this type of polyethylene after bedding in has finished taking place is less than 10 micra per year. This wear rate is similar to the wear rate of metal-on-metal and ceramic-on-ceramic articulations. Retrieval specimens up to 3 years after … shanty corp